IQAir Cleanroom H13
|
|
IQAir Cleanroom H13
|
The IQAir Cleanroom H13 has been designed
specifically for the removal of airborne particles. The systems feature
the highest air delivery and longest filter life of any IQAir particle
filter system. To allow for maximum air delivery the systems contain no
gas phase filtration.
Applications
- Microbiological control in hospitals
- Clean production areas
- Clean research areas
- Pharmaceutical laboratories
|
|
All systems come complete with filters, owners manual, set of 4
casters (except GCX series and Cleanroom H13), 6 foot power cord,
hand-signed certificate of guaranteed performance, user guide video
(both VHS and DVD) and remote control with batteries (except compact
model).
| Specifications
|
Other Information
|
|
|
1. User Control Panel
2. Carrying Handle
3. No-Draft Diffuser
4. Cleanroom-Grade HyperHEPA Filter
5. Snap-Open Locking Arms
6. High-Performance Centrifugal Fan
7. Advanced Fan Control
8. Pre-Max Pre-Filter (Class F9)
9. Dual Floor Air Intake
| General
|
| Number of Selectable Fan Speeds
|
5
|
|
Air Delivery (with new filters installed) per Speed
|
1 - 45 cfm
2 - 70 cfm
3 - 90 cfm
4 - 155 cfm
5 - 270 cfm
|
|
Maximum Coverage Area
|
1200 sq ft
|
|
System Efficiency for Particles
|
99.97% or more at 0.3 microns
99% for smaller particles
|
|
Power Requirements
|
115 VAC 50-60 Hz The entire electrical system is UL certified.
|
|
Energy Consumption (Max)
|
195 W
|
|
Dimensions
|
H 32" W 15" D 16"
|
|
Net Weight (including filters)
|
33 lbs
|
|
Warranty Period
|
1 year on unit including fan motor, excluding filters
|
| Filters
|
|
Filter Configuration
|
1 Pre-Max Pre-Filter and 1 HyperHEPA filter (fine dust and micro dust filtration)
|
|
Pre-Filter
|
32 sq ft mini-pleat fine dust filter
|
|
HEPA Filter Efficiency and Surface Area
|
99.97% at .3 microns, 44 sq ft.
|
|
Filter Frame Material
|
Expanded polystyrene (EPS), chlorofluorocarbon (CFC) - free
|
|
|
Average Filter Life
|
Pre-Filter 6-18 months, HEPA up to 2 years (filter life is dependant on the operating environment)
|
| Housing
|
|
Housing Material
|
ABS(UV-stabilized), non-offgasing, high-impact resistant, eight internal shock absorbers
|
|
Color of Main Housing/Arms
|
Light Gray/White
|
|
Air Intake
|
Two side openings at base of unit
|
|
Air Outlet
|
Via diffuser with horizontal 320 degree, 77 sq inch opening on top of unit
|
| Fan
|
|
Fan Motor
|
Centrifugal fan, backward curved, single inlet, UL/CSA registered.
Maintenance-free steal ball bearings. Speed regulation includes voltage
reductions via capacitor switching
|
| Electronic Control Panel
|
|
Control Panel Design
|
4 key touch pad, 32 character LCD display
|
|
Key features
|
Display of air delivery for each speed, display of remaining filter life, automatic timer
|
|
Display Languages
|
English, French, German, Italian, Spanish
|
|
Remote control
|
Supplied with unit (includes batteries)
|
|
Professional Control Of Airborne Particulates
Larger HyperHEPA filter
The Cleanroom offers a larger HyperHEPA filter (ca. 4.1 m2, instead of
3.7 m2). Also the unit has a larger pre-filter (ca. 4.1 m2, instead of
2.3 m2), therefore more capacity and longer life. This feature is
particularly useful when the systems are in 24-hour non-stop use.
Higher efficiency HyperHEPA filter
Features H13 class certified HEPA filter.
Individually tested and certified HyperHEPA replacement filters
Ensures continued certified filtration efficiency.
Anti-microbially treated HyperHEPA
HEPA filter is treated
with antimicrobial agents that kill microorganisms, especially
bacterium that cause diseases upon contact.
Anti-microbially treated pre-filter
Pre-filter is treated with antimicrobial agents that kill microorganisms, especially bacterium that cause diseases upon contact.
Higher air flow rate
The airflow rate is higher since there is no gas filtration in this
device. A gas filter would reduce the air flow rate and add to filter
replacement costs and it does not provide any infection control
benefits. High air delivery rates are also important to achieve high
air changes per hour (ACH) and when the system is used to create
negative/positive pressure differences (e.g. for isolation purposes).
Anti-Tampering Features
A special cable lock avoids the system from becoming disconnected
accidentally. In addition, a Special arm lock prevents tampering with
the system by unauthorised users.
Positive and Negative Pressure Environments
Each IQAir
Cleanroom system can be used as a recirculation device or it can be
combined with IQAir's ducting adapters InFlow W125 or OutFlow W125 to
create positive and negative pressure environments. The creation of
negative pressure helps to contain harmful particles, such as
microorganisms, in a particular area (e.g. TB isolation). Just see all
the IQAir accessories so you know the many different ways you can deploy an IQAir.
The creation of positive pressure helps to protect clean areas from
contaminants entering from adjacent rooms (e.g. protective isolation of
immuno-compromised patients, controlled environments for medical device
manufacturing).
Decentralised Airborne Infection Control in Health-Care Facilities
Airborne pathogens in health-care environments pose a particular risk
to immunocompromised patients who may inhale fungal spores, bacteria
and viruses. Airborne microorganisms can not only complicate recovery
from surgery, but can also lead to life-threatening infections,costing
health-care services hundreds of millions every year.
Hospital-acquired aspergillosis for example has been recognised
increasingly as a cause of severe illness and high mortality in
immunocompromised individuals, e.g. patients undergoing chemotherapy
and/or organ or bone marrow transplants. In the light of the marked
increase in nosocomial infections over recent years, many of which are
caused by drug-resistant pathogens, the importance of using
high-efficiency air filtration systems beyond the confines of so-called
"critical areas" (such as operation theatres) has once again been
emphasised. Both the World Health Organisation (WHO) and the Centers
for Disease Control and Prevention (CDC), advise that, wherever
possible, preventive infection control measures should be implemented
to reduce the risk of nosocomial infections.
|
|
Product Reviews
|
|
|